deskontroller LITE V3 range

Art-Net LED Pixel Controllers

deskontroller LITE V3 converts Art-Net over Ethernet into digital signals for addressable Pixel LED installations. All six models share the same professional hardware platform, with up to 32 DATA outputs in normal mode, browser-based configuration and capacities from 32U to 192U.

deskontroller LITE V3 Art-Net LED controller family: six models from 32 to 192 universes, with 32 DATA outputs in normal mode
Direct model access

Choose your LITE V3 model

Not sure which capacity you need? Use the model selection guide.

How the system works

From Art-Net to Pixel LED in three steps

The deskontroller connects your lighting-control network to the digital LEDs. Your software sends Art-Net universes through Ethernet, and the controller converts and distributes that data to the Pixel LED outputs.

1 · Control

Art-Net over Ethernet

Lighting, pixel-mapping or media software sends the required universes to the deskontroller through the Ethernet network.

2 · Controller

deskontroller LITE V3

The controller receives the Art-Net data, assigns it to the required physical outputs and generates the selected Pixel LED protocol.

3 · LEDs

Pixel LED output

The digital signal is sent to addressable LED strips, modules or fixtures. LED power is supplied separately according to the electrical design of the installation.

Designed for addressable LEDs

Why use Pixel LED / SPI for large LED installations?

DMX512 remains an excellent standard for conventional lighting fixtures. Addressable Pixel LED installations, however, can require thousands of individual RGB or RGBW channels, making direct digital pixel protocols a much more practical way to connect the controller to the LEDs.

Multiple universes per pixel output

A conventional DMX line carries one universe of up to 512 channels. With deskontroller, multiple Art-Net universes can be converted and distributed through each Pixel LED output, depending on the selected LITE V3 model.

Simpler pixel addressing

Serial addressable pixels receive their data according to their position in the pixel chain. There is normally no need to configure a separate DMX address on every individual pixel.

High-density LED control

A single controller can handle thousands of RGB or RGBW pixels while distributing the load across multiple physical outputs. This makes the architecture well suited to large pixel-mapping and decorative LED projects.

Wide choice of Pixel LED protocols

Modern addressable LEDs are available with many data-only and DATA + CLOCK protocols. This gives system designers a wide choice of pixel types, performance levels and LED supply voltages for different installations.

The basic workflow stays simple: control the project with Art-Net over Ethernet, let the deskontroller convert the data, and send the required digital protocol directly to the Pixel LEDs.

deskontroller LITE V3 scalable Art-Net Pixel LED controller capacity from 32U to 192U

One hardware platform

The same controller family, Web UI and installation workflow across all six capacity levels.

32 physical outputs

The complete range provides 32 DATA outputs in normal mode, distributed across 8 RJ45 connectors.

Upgradeable capacity

Models from 32U to 160U can be upgraded later by key, up to 192U.

European manufacturer

Designed and manufactured in Europe, with direct support and a 5-year warranty.

Quick orientation: which LITE V3 model do you need?

All LITE V3 models use the same hardware platform. The main difference is the total Art-Net universe capacity and, therefore, how many universes can be assigned to each Pixel LED output.

1–2 universes per output

32U / 64U

For projects with lower data requirements per pixel line, or when the installation is distributed across more physical outputs.

  • 32 or 64 Art-Net universes
  • 1 or 2 universes per output in normal mode
  • Up to ~10,880 RGB pixels
3–4 universes per output

96U / 128U

For installations that need more pixels on each output while keeping the load distributed across the controller.

  • 96 or 128 Art-Net universes
  • 3 or 4 universes per output in normal mode
  • Up to ~21,760 RGB pixels
5–6 universes per output

160U / 192U

For high-density installations where more universes and more pixels must be carried by each physical output.

  • 160 or 192 Art-Net universes
  • 5 or 6 universes per output in normal mode
  • Up to ~32,640 RGB pixels

Important: universe capacity is not an FPS guarantee. Actual refresh rate depends on the selected model, Pixel LED protocol, output mode, configuration and amount of data transmitted per output. If you are between two models, calculate the required universes per output first. For a detailed sizing check, use the model selection guide.

Pixel LED signal distribution

From the controller to the pixels: RJ45, CAT6 and output adapters

Every LITE V3 uses the same physical output architecture. After receiving Art-Net through Ethernet, the controller generates the selected Pixel LED signals and distributes them through 8 dedicated RJ45 output connectors. CAT6 cable carries these signals toward the LED installation, where RJ45-to-terminal adapters provide convenient connections to the pixel lines.

deskontroller LITE V3 Pixel LED output path using RJ45 connectors, CAT6 cable and terminal adapters

8 dedicated output connectors

The 8 RJ45 connectors distribute Pixel LED signals from the controller. They are output connectors and are separate from the Ethernet connection used to receive Art-Net.

CAT6 signal distribution

Standard CAT6 cable carries the digital control signals from the controller toward the first pixels, helping simplify long cable runs and centralised installations.

RJ45-to-terminal adapters

The external adapters break out the signals from each RJ45 connector into accessible terminal connections for wiring the individual Pixel LED lines.

Up to 4 DATA outputs per RJ45

In normal mode, each RJ45 provides four independent DATA signals: D1, D2, D3 and D4, giving a total of 32 Pixel LED outputs across the controller.

The RJ45/CAT6 wiring carries Pixel LED control signals, not LED power. Power for the strips, modules or fixtures must be supplied separately according to the electrical requirements of the installation.

32 outputs vs 16 outputs

Normal mode and 16-output modes

The same LITE V3 hardware can operate with 32 DATA outputs or 16 active pixel lines, depending on the selected output mode and Pixel LED protocol. This directly affects how the controller's total universe capacity is distributed across the outputs.

deskontroller LITE V3 comparison of 32 DATA outputs in normal mode and 16 pixel lines in V1 or DATA plus CLOCK modes

Normal mode · 32 DATA outputs

Each RJ45 uses D1, D2, D3 and D4 as independent DATA signals, providing 4 outputs per RJ45 and 32 DATA outputs in total.

V1 data-only · 16 DATA outputs

V1 mode uses D1 and D2 as DATA on each RJ45, providing 2 outputs per RJ45 and 16 DATA outputs in total.

DATA + CLOCK · 16 pixel lines

Clocked protocols use D1 and D2 for DATA, while D3 and D4 carry the corresponding CLOCK signals. This provides 16 DATA + CLOCK pixel lines.

The controller's total Art-Net universe capacity does not change with the output mode. With 16 active DATA outputs, that capacity can be distributed across fewer lines, allowing more universes per active output.

Compare the deskontroller LITE V3 range

All LITE V3 models use the same hardware platform. Compare the Art-Net capacity of each model and how that capacity is distributed across 32-output normal mode or the 16-output modes.

Model Art-Net universes Approx. RGB pixels Universes / output Approx. RGB pixels / output
32U 32 ~5,440 1 normal / 2 with 16 outputs ~170 normal / ~340 with 16 outputs
64U 64 ~10,880 2 normal / 4 with 16 outputs ~340 normal / ~680 with 16 outputs
96U 96 ~16,320 3 normal / 6 with 16 outputs ~510 normal / ~1,020 with 16 outputs
128U 128 ~21,760 4 normal / 8 with 16 outputs ~680 normal / ~1,360 with 16 outputs
160U 160 ~27,200 5 normal / 10 with 16 outputs ~850 normal / ~1,700 with 16 outputs
192U 192 ~32,640 6 normal / 12 with 16 outputs ~1,020 normal / ~2,040 with 16 outputs

RGB figures use approximately 170 pixels per Art-Net universe. RGBW uses approximately 128 pixels per universe. These figures represent data capacity, not a fixed refresh rate: actual FPS depends on the Pixel LED protocol, number of pixels transmitted per output and configuration.

Upgradeable capacity

Start with the capacity you need and upgrade later

Models from 32U to 160U can be upgraded later by key, up to 192U, without replacing the controller. This allows you to choose the Art-Net universe capacity required today and increase it later if the installation grows.

Need more precision?

Confirm the right model before buying

If you know your approximate number of pixels, Art-Net universes or required pixel outputs, use the model selection guide to calculate the capacity and universes per output your installation needs. You can also contact us if you want us to check your project.

Frequently asked questions before buying

Do all LITE V3 models have the same outputs?

Yes. All models use the same hardware platform. In normal mode they provide 32 DATA outputs across 8 RJ45 connectors. V1 data-only and DATA + CLOCK operation use 16 active pixel lines.

Does the controller power the LEDs?

No. The deskontroller provides the digital control signals. LED power must be supplied separately according to the voltage, current and power-distribution requirements of the installation.

Can I upgrade to more universes later?

Yes. Models from 32U to 160U can be upgraded by key to a higher universe capacity, up to 192U, without replacing the controller.

Do I need proprietary control software?

No. The controller receives standard Art-Net data and can be used with compatible lighting, pixel-mapping and media-server software.

Should I choose the model only by total pixel count?

No. Total pixel count is only part of the calculation. The required universes per output, number of physical pixel lines, Pixel LED protocol and refresh-rate requirements should also be considered.

What if I am not sure which model I need?

Use the model selection guide to calculate the required capacity. If you already know your approximate pixel count, universe count or number of outputs, you can also contact us and we can check the project.

Professional purchase support

Need a quick commercial or technical confirmation?

If you already know your approximate project size, we can help you confirm the most suitable deskontroller LITE V3 before purchase.

Shop the deskontroller LITE V3 range

Choose the LITE V3 model that matches the Art-Net universe capacity required by your Pixel LED project.

Loading...
Back to top