Resolume + Art-Net hardware

Art-Net controller compatible with Resolume

Resolume Arena is a live visual performance and media server environment that can combine video, live inputs, generative Sources and real-time effects, then map the result to DMX fixtures and send it over standard Art-Net. For Pixel LED installations, deskontroller LITE V3 provides the independent hardware layer that receives those Art-Net universes and distributes them to the physical LED lines.

The workflow remains clear from software to hardware: Resolume Arena handles the composition, visual processing and Advanced Output, while deskontroller provides 32 active outputs in normal mode or 16 active outputs in V1 / DATA + CLOCK, with a capacity range from 32U to 192U.

Standard Art-NetIntegrates into the existing Resolume network workflow.
32 physical linesDistribute visuals across shorter and clearer runs in normal mode.
32U to 192UChoose from 512 to 3072 channels per output in normal mode.
Professional platformEuropean manufacturer, direct support and 5-year warranty.
Resolume running on a laptop beside a deskontroller LITE V3 Art-Net controller and a professional Pixel LED installation
Why it fits

Why deskontroller LITE V3 fits Resolume projects

Resolume is commonly used where visuals must move quickly from a composition to a real stage, club, exhibition, set or permanent installation. The controller should keep that output layer just as clear and manageable as the content workflow.

Live visuals and generative content

Resolume Arena can combine video, live inputs, generative Sources and real-time effects, then map selected content to DMX fixtures in Advanced Output and send it over Art-Net to the Pixel LED hardware layer.

More physical lines when the project needs them

With 32 active outputs in normal mode, the installation can use shorter runs, clearer zones and a physical layout that is easier to patch, document and service.

One platform across the complete range

The hardware, browser-based setup and output structure remain consistent from 32U to 192U. Only the available capacity changes with the model.

Workflow overview

From Resolume composition to Pixel LED control

The workflow has two clearly separated cabling stages: a standard Ethernet network connection carries Art-Net from the computer to the controller, while CAT6 UTP cable is recommended from the controller outputs towards the Pixel LED installation.

Resolume workflow showing composition software, standard Ethernet network cable, deskontroller LITE V3, CAT6 UTP output distribution and a Pixel LED installation
Resolume sends Art-Net through the standard network connection. deskontroller then distributes the installation through 32 outputs in normal mode or 16 outputs in V1 / DATA + CLOCK, using CAT6 UTP for the output runs.

Create, process and map in Resolume

Build the composition from video, live inputs, effects or generative Sources, then define the required slices, fixtures and Lumiverses in Advanced Output according to the real installation.

Send Art-Net over the network

Use the project network to send the selected universe range from Resolume to the deskontroller target IP.

Distribute the physical outputs

Use the controller as the hardware output layer, with CAT6 UTP runs of up to 100 m from each RJ45 output to the corresponding adapter and Pixel LED lines.

Cabling distinction: the computer-to-controller connection is a standard Ethernet network link. For the SPI output runs from deskontroller to the adapters, use four-pair CAT6 UTP without outer shielding for the most reliable signal behaviour.

Output scaling

Keep 32 physical outputs and scale the channels per output

Every deskontroller LITE V3 model provides the same 32-output normal-mode structure. Moving up the range increases the number of Art-Net universes—and therefore the number of channels—available on each physical output.

Resolume output scaling with deskontroller LITE V3 models from 32U to 192U, showing 32 outputs and 512 to 3072 channels per output
In normal mode, model capacity scales from 512 channels per output on 32U to 3072 channels per output on 192U, while keeping the same 32 physical output structure.

Commercial advantage: when a Resolume project uses many independent visual elements or physical zones, more outputs allow the content structure to follow the real installation instead of concentrating the complete load into only a few long lines.

Project fit

What to define before choosing the model

Once Resolume compatibility is confirmed, the buying decision depends on the real output load and how the installation needs to be distributed.

Total channels and universe count

Calculate the total Art-Net requirement from the fixtures, RGB or RGBW format and the size of the Advanced Output configuration.

FPS and operating margin

Review the target refresh rate together with the complete universe load, especially for live, touring, broadcast or camera-sensitive work.

Physical output distribution

Decide how many independent LED lines and zones the project needs, and whether shorter runs will simplify cabling, power distribution and maintenance.

Technical setup reference

Need the complete Resolume setup workflow?

The technical guide covers DMX preferences, network adapter selection, Advanced Output, Lumiverse target IP, fixture configuration and a practical 96U RGB example.

Choose the right deskontroller LITE V3 for your Resolume project

Share the total universe count, RGB or RGBW format, required FPS, installation type and approximate number of physical LED lines. We can help you confirm the right capacity before purchase.

Resolume is a trademark or registered trademark of Resolume B.V. deskontroller is independent third-party hardware and is not affiliated with or endorsed by Resolume B.V. All company and product names referenced on this page are trademarks or registered trademarks of their respective owners.

Loading...
Back to top