Art-Net to SPI LED Controller for Addressable Pixel Installations
deskontroller LITE V3 receives Art-Net over Ethernet and converts the network data into digital signals for addressable SPI / Pixel LED installations. The controller provides up to 32 physical DATA outputs in normal mode, with six models from 32 to 192 Art-Net universes.
SPI / Pixel LED: serial digital control for addressable LEDs
In Pixel LED installations, the term SPI is commonly used for the family of fast serial digital protocols that send colour data from the controller to addressable LEDs. Not every protocol uses the same electrical or timing structure: some use a single DATA signal, while others use separate DATA and CLOCK signals.
Sequential pixel addressing
In common serial Pixel LED families, each pixel takes the data intended for its position in the chain and passes the remaining data to the next pixel. This normally removes the need to configure an individual DMX start address on every pixel.
Designed for high channel counts
An RGB pixel uses three control channels and an RGBW pixel uses four. Large installations therefore create thousands of channels very quickly. Serial Pixel LED protocols provide an efficient physical way to deliver this data to long chains of addressable LEDs.
Fast digital LED protocols
Many common data-only Pixel LED families use high-speed serial transmission, while DATA + CLOCK protocols use a separate clock signal and have protocol-dependent timing. The real refresh rate depends on the protocol and the amount of pixel data transmitted on each line.
Wide choice of LED technologies
Pixel LED systems are available as strips, nodes, modules, matrices and custom assemblies, with different RGB or RGBW formats, pixel densities, control ICs and LED supply voltages.
Why serial Pixel LED control works well for large installations
DMX512 remains an excellent standard for conventional lighting fixtures. Pixel LED projects have a different requirement: very large numbers of individually controlled channels must be delivered efficiently to LED strips, nodes and modules.
Multiple universes on one pixel line
A conventional DMX512 line carries one universe. With an Art-Net to Pixel LED controller, several Art-Net universes can be assigned to a single Pixel LED output when the controller capacity, LED protocol and required refresh rate allow it.
Practical installation and maintenance
Sequential data distribution helps installers organise and document each pixel line consistently. When replacing sections or diagnosing faults, correct LED direction, control IC, line length and signal continuity remain important.
Practical for thousands of pixels
Large installations can be divided into multiple digital pixel lines while Art-Net transports the required universes over the Ethernet network. The conversion to the LED protocol takes place close to the physical installation.
Flexible system design
Different Pixel LED technologies provide different combinations of speed, colour depth, signal structure, voltage and physical format. This gives designers a wide range of options for architectural, scenic, immersive and custom LED projects.
Art-Net and SPI perform different jobs: Art-Net transports lighting data across the Ethernet network; the Pixel LED protocol carries that data from the controller to the addressable LEDs.
From Art-Net software to the final Pixel LED line
The controller sits between the network and the LEDs. Your lighting or pixel-mapping software works with Art-Net universes; deskontroller receives those universes, maps them to the required outputs and generates the digital protocol understood by the selected pixels.
Art-Net over Ethernet
Compatible lighting software, media servers, consoles or creative systems send the required Art-Net universes through the Ethernet network.
deskontroller LITE V3
The controller receives the Art-Net data, applies the configured patch and Pixel LED protocol, and generates the corresponding digital output signals.
DATA or DATA + CLOCK
The resulting serial signals are sent to addressable strips, nodes, modules or other Pixel LED devices. LED power is supplied separately according to the electrical design.
DATA-only and DATA + CLOCK protocols use the outputs differently
The Pixel LED protocol determines how the physical outputs are used. LITE V3 provides a 32-DATA-output normal mode and 16-line structures for V1 data-only operation or protocols that require separate DATA and CLOCK signals.
Normal · 32 DATA outputs
For standard data-only Pixel LED operation, D1, D2, D3 and D4 work as independent DATA signals across the eight RJ45 output groups.
V1 · 16 DATA outputs
For DATA-only protocols, V1 is a selectable 16-output mode with two DATA signals per RJ45 group. It redistributes the same total controller universes across fewer active outputs.
DATA + CLOCK · 16 pixel lines
When a clocked protocol is selected, the controller uses 16 active DATA + CLOCK pixel lines, with two DATA signals and their corresponding CLOCK signals per RJ45 group. This is distinct from manually enabling V1 for DATA-only operation.
For the complete physical wiring, RJ45 adapters, CAT6 distribution and 32-versus-16-output explanation, see the dedicated output architecture page.
What to define before choosing an Art-Net to SPI controller
Once the Pixel LED technology is defined, controller selection comes down to the real amount of data and how it must be distributed across the installation.
Total universes
Calculate the required Art-Net universe count from the number of individually controllable RGB or RGBW pixels (control ICs), which may differ from the number of physical LEDs.
Universes per output
Check how many universes each physical pixel line must carry. This can be just as important as the total universe count.
Pixel LED protocol
Confirm the LED control IC and whether it uses DATA only or DATA + CLOCK, as this determines the required output structure and timing.
Required refresh rate
Refresh rate depends on the selected protocol and the amount of pixel data transmitted by each output, not simply on the controller model.
One Art-Net to Pixel LED platform, from 32 to 192 universes
All LITE V3 models use the same hardware platform and Pixel LED output architecture. The model determines the available Art-Net universe capacity and how many universes can be assigned to each active output.
Choose the required universe capacity
The range covers 32U, 64U, 96U, 128U, 160U and 192U. Use the model selection guide when you need to calculate total universes and the required capacity per physical output.
Upgrade later if the installation grows
Models from 32U to 160U can be upgraded later by key to a higher universe capacity, up to 192U, without replacing the controller.
Use the software that fits your Pixel LED project
The software creates and sends the Art-Net data; deskontroller provides the hardware conversion and Pixel LED output layer. No proprietary lighting-control application is required.
MADRIX
For professional Pixel LED and lighting-control workflows using Art-Net output.
Resolume
For visual and media-server workflows where LED structures are controlled through Art-Net.
MadMapper
For mapping, installations and creative LED projects using Art-Net output.
TouchDesigner
For interactive, generative and custom Pixel LED systems using Art-Net workflows.
Where Art-Net to SPI / Pixel LED control fits best
This architecture is designed for projects where Art-Net universes from a standard Ethernet network must control large numbers of addressable digital LEDs.
Architecture and permanent installations
For façades, structures and permanent LED systems using strips, nodes or modules with individual pixel control.
Stage, touring and broadcast
For scenic and production environments that need high-channel-count Pixel LED elements integrated into standard Art-Net workflows.
Pixel mapping, immersive and AV projects
For media-server, interactive and custom installations using digital LED strips, nodes, matrices and other addressable formats.
Art-Net to SPI questions before buying
Is SPI the same as Art-Net?
No. Art-Net transports lighting data through the Ethernet network. SPI / Pixel LED protocols are used on the output side between the controller and the addressable LEDs.
Are all Pixel LED protocols the same?
No. Some use a single DATA signal, others use DATA + CLOCK, and different LED families have different timing, colour depth and electrical requirements.
Do I have to program an address into every pixel?
Normally not with common serial Pixel LED families. The pixels receive data sequentially according to their position in the line rather than requiring an individually configured DMX start address.
Does the controller power the LEDs?
No. The controller provides the digital control signals. LED power must be designed and supplied separately according to the voltage, current and distribution requirements of the installation.
Can different outputs use different Pixel LED protocols?
No. The Pixel LED chipset and related protocol settings are configured globally on the controller, so the outputs operate with the selected compatible LED family.
How do I choose the correct LITE V3 model?
Calculate the total Art-Net universes and then check how many universes are required on each physical pixel line. Use the model selection guide for the complete sizing process.
Need an Art-Net to SPI solution for your Pixel LED project?
If you know the approximate pixel count, Pixel LED protocol and number of physical lines, we can help confirm the required LITE V3 capacity before purchase.